  1. Symptom – Refrigeration Leak

    In a Viper unit, there are many brazed joints and refrigeration components with the potential for leaking refrigerant. Listed are the more common components to check:

    1. Evaporator (foam pack): inlet, outlet and around faceplate.

    2. Accumulator

    3. Receiver

    4. Condenser

    5. All brazed joints

    Note: pressurize with nitrogen and use bubbles to check. A sniffer may pick up traces of refrigerant in foam.