Counter Cutout Template: WITH Legs

IDC Pro Installation Genie — Begin Your Installation — Dispenser Placement - Drip Tray Configuration

  1. Counter Cutout Template: WITH Legs

    Unit is very heavy!! Take proper safety precautions when lifting and moving.

    Unit is front heavy!! Take proper safety precautions when lifting and moving.

    Table Lift is recommended to properly lift and move the IDC Pro.

    Route Beverage Tubing and Drain Tubing through the 9”x12” opening. This will allow a nice approach to the cold plate inlet fittings and proper slope to the drain. Be sure to route the beverage tubing on top of the tubing support bar on the bottom of the dispenser, this will avoid the tubing from sitting on the counter and being visible. Do not route the drain through the tubing support bar as it will prevent proper drainage

    Note: You may need to use a 90° fitting if the drain tubing doesn’t lay flat on the counter.